Magnetic Inductive Flow Meter
Type: EP
Development at the highest level
“High end” simulation technology enables the analysis and coupling of different models such as CSD (FEM), CFD, CEM, FSI, TFSI, saving much of the time that would have had to be invested in finding solutions in the past. This is our way in the future to solve highly complex measurement tasks for our customers.
By using the latest technologies, we are able to quickly identify and overcome application obstacles and provide optimal solutions for our customers.

Details
Applications
Volume flow measurement of electrically conductive liquids, slurries and pastes without loss of pressure.
Special features
- High measurement accuracy
- No maintenance required
- No pressure drop
- Wide spectrum of electrode materials.
- Many liners available
- Inexpensive grounding electrode available instead of grounding rings, also available special materials like e. g. tantalum.
- Large selection of process connections.
Technical data
Sensor EPS
- Body: Coated steel
- Process connections: Steel or stainless steel flanges (EN1092, ASME, JIS) Food connections DIN11851, Tri-Clover® (other connections on request)
- Linings: Hard rubber, soft rubber, PTFE, EPDM, ceramic
- Measuring and grounding electrodes: stainless steel 1.4571, Hastelloy, tantalum, platinum (grounding rings and other materials on request)
- 2 / 3 / 6 / 10mm inner diameter with process connection G½” (m) or ½” NPT(m)
- Nominal diameters: DN15 bis DN 1200 (others on request)
- Nominal pressure: PN40, ASME Cl150/300 DN15 to DN300
PN16, ASME Cl150 DN50…DN600
PN10, ASME Cl150 DN200 to DN1200 (higher pressure ratings on request)
- Process temperature:
- -10°C to +70°C EPDM
- 0°C to +95°C Hardrubber (Ebonite)
- -20°C to +150°C PTFE and Ceramic
- Range: 0,5 m/s – 10 m/s
- Accuracy: ± 0.3 % of measured value ± 0.01 % * (Q at 10 m/s) (under reference conditions)
- Repeatability: ± 0.15 % of measured value ± 0.005 % * (Q at 10 m/s) (under reference conditions)
- Protection class: Standard IP67 (EN60529), IP68 on request
Transmitter UMF2
- Installation: integral or remote
- Housing: Aluminum die cast, coated
- Auxiliary power: 115/230 VAC 50/60Hz, 10VA ‘ 24VDC, 10W
Outputs:
- Analog: 1x 0/4-20mA active, galvanically isolated
- Pulse: passive, galvanically isolated, 24V, 60mA
- Status: passive, galvanically isolated, 24V, 60mA
- Ambient temperature: -20°C to +60°C
- Protection class: IP67 / IP68 on request
- Diagnostic Functions: Empty pipe detection, exciter current monitoring
- Electromagnetic compatibility: EMC Directive 2014/30/EU (EMC)
- Low Voltage Directive: 2014/35/EU (LVD)
Communication
HART® Protocol
Downloads
Video