Heinrichs Messtechnik GmbH • Robert-Perthel-Straße 9 • 50739 Köln • Tel.: +49 (221) 49708-0info@heinrichs.eu

Type EP

Magnetic Inductive Flow Meter

csm_EPS.png: Magnetic Inductive Flow Meter
  • High measurement accuracy
  • High repeatability
  • Various linings
  • Grounding electrode

Development at the highest level

“High end” simulation technology enables the analysis and coupling of different models such as CSD (FEM), CFD, CEM, FSI, TFSI, saving much of the time that would have had to be invested in finding solutions in the past. This is our way in the future to solve highly complex measurement tasks for our customers.

By using the latest technologies, we are able to quickly identify and overcome application obstacles and provide optimal solutions for our customers.

→ Downloads

Send a request

Applications

Volume flow measurement of electrically conductive liquids, slurries and pastes without loss of pressure.

Special features

  • High measurement accuracy
  • No maintenance required
  • No pressure drop
  • Wide spectrum of electrode materials.
  • Many liners available
  • Inexpensive grounding electrode available instead of grounding rings, also available special materials like e. g. tantalum.
  • Large selection of process connections.

Technical data

Sensor EPS

  • Body: Coated steel
  • Process connections: Steel or stainless steel flanges (EN1092, ASME, JIS) Food connections DIN11851, Tri-Clover® (other connections on request)
  • Linings: Hard rubber, soft rubber, PTFE, EPDM, ceramic
  • Measuring and grounding electrodes: stainless steel 1.4571, Hastelloy, tantalum, platinum (grounding rings and other materials on request)
  • 2 / 3 / 6 / 10mm inner diameter with process connection G½” (m) or ½” NPT(m)
  • Nominal diameters: DN15 bis DN 1200 (others on request)
  • Nominal pressure: PN40, ASME Cl150/300 DN15 to DN300
    PN16, ASME Cl150 DN50…DN600
    PN10, ASME Cl150 DN200 to DN1200 (higher pressure ratings on request)
  • Process temperature:
  • -10°C to +70°C EPDM
  • 0°C to +95°C Hardrubber (Ebonite)
  • -20°C to +150°C PTFE and Ceramic
  • Range: 0,5 m/s – 10 m/s
  • Accuracy: ± 0.3 % of measured value ± 0.01 % * (Q at 10 m/s) (under reference conditions)
  • Repeatability: ± 0.15 % of measured value ± 0.005 % * (Q at 10 m/s) (under reference conditions)
  • Protection class: Standard IP67 (EN60529), IP68 on request

Transmitter UMF2

  • Installation: integral or remote
  • Housing: Aluminum die cast, coated
  • Auxiliary power: 115/230 VAC 50/60Hz, 10VA ‘ 24VDC, 10W

Outputs

  • Analog: 1x 0/4-20mA active, galvanically isolated
  • Pulse: passive, galvanically isolated, 24V, 60mA
  • Status: passive, galvanically isolated, 24V, 60mA
  • Ambient temperature: -20°C to +60°C
  • Protection class: IP67 / IP68 on request
  • Diagnostic Functions: Empty pipe detection, exciter current monitoring
  • Electromagnetic compatibility: EMC Directive 2014/30/EU (EMC)
  • Low Voltage Directive: 2014/35/EU (LVD)

Communication

HART® Protocol

Operating manual

application/pdf; charset=binary

EP_BA_16_en

EP – EN

1,1 MB

Datasheet

application/pdf; charset=binary

EP_DA_05_en

EP/UMF2(B) – EN

639 KB
Heinrichs Messtechnik GmbH

Robert-Perthel-Straße 9
50739 Köln
Germany

Please activate JavaScript

Cookies & Features

This website uses cookies to provide content and features. Details of the technologies used can be found in our privacy policy.

Essential Cookies

Session data such as language selection or spam protection - you can't do without it.

Analytics
Google
loading
loading