Coriolis Mass Flow Meter – TMU High Flow
Coriolis Mass Flow Meter – TMU High Flow
- High flow rate ranges up to 2.200 t/h
- Meter sizes up to DN 400 / 16″
- Pressure resistant up to 40 bar
- Integrated heating jacket (optionally)
- OIML R117
Details
Applications
TMU High Flow Coriolis Mass Flow Meter are used where high flow values in piping systems up to 400 mm / 32 inch and up to 2,200 t/h have to be measured safely and accurate.
The instruments offers a very long term stable zero point, are extremely robust and thus are suitable in particular for applications which can be found in oil and gas loading stations, for measurements in pipeline systems on-shore and off-shore. A very special body construction allows the opening of the meter for service works – thus the instruments don´t have to be extracted for most of the inspections needed.
Special features
- Meter sizes up to DN 400 / 16″
- Measuring ranges up to 2.200 t/h
- Custody transfer approval
- Heating system
- PROFIBUS, FIELDBUS, MODBUS – Communication
Technical data
Sensor
- Sensor: TMU
- System: Coriolis
- Measuring ranges: up to 2.200 t/h (liquids)
- Accuracy:
- Gas: ±0.5 % of actual flowrate ± ZP stability
- Liquids: ±0.1 % of actual flowrate ± ZP stability
- Wetted parts:
- 1.4571 (316 TI)
- Hastelloy C-22
- Tantalum
- Sensor enclosure:1.4301 (304L)
- Process connections:
- Flanges acc. DIN EN 1092-1, ASME B16.5-2003, JIS B2200-2004
- Thread: G, NPT
- others on request
- ATEX / IECEx Approval: II 1/2G Ex ia IIC T2…T6 Ga/Gb
- Max. Process pressure: PN40. High pressure design on request.
- Process temperature: -40…+260°C
- Ambient temperature: -40…+60°C
- Ingress protection: IP67 (EN60529)
Transmitter:
- Model: UMC4
- Power supply: 19…36 VDC
- Signal outputs: (galvanically separated)
- Analogue: 2 x 4-20 mA HART®, passive (Standard or Ex „i“)
- Pulse output (or Frequency output): passive, via optocoupler as Frequency output max. 1 KHz
- Status output: passive, via optocoupler
option: second pulse output 90° phase shifted
- Ambient temperature: -40…+55°C
- Ingress protection: IP68 (EN 60529)
- ATEX Approval:
- Field housing: II 3(1)G Ex ec [ia Ga] IIC T6..T3 Gc
(protection class terminal compartment Ex d) - Rack Mount Housing: II 3G Ex ec [ia Ga] IIC T3-T4 Gc
(Rack Mount), Ambient up to 60°C
- Field housing: II 3(1)G Ex ec [ia Ga] IIC T6..T3 Gc
- CE-Marking:
- 2014/30/EU (EMC)
- 2014/34/EU (ATEX)
- 2014/35/EU (LVD)
- 2014/68/EU (PED)
- Communication: HART®
Certificates and Approvals
- ATEX / IECEx
- DMT 01 ATEX E 149 X
II 1/2G Ex ia IIC T6 … T2 Ga/Gb - IECEx BVS 11.0084X
Ex ia IIC T6 … T2 Ga/Gb
(Approval for Zone 0 inside flow tubes)
- DMT 01 ATEX E 149 X
- CSA (North America)
- 70171067
Class I, Div. 1 and Div. 2 Gr. ABCD
Ex ia IIC T5…T2 Ga
Class I, Zone 0, AEx ia IIC T5…T2 Ga
- 70171067
- NEPSI (China)
- Remote: GYJ22.1873X
Ex ia II C T2…T6 Ga/Gb
- Remote: GYJ22.1873X
- CS (Korea)
- 12-KB4B0-0116X
Ex ia IIC T6…T2
- 12-KB4B0-0116X
- EAC (Eurasian Union)
- RU C-DE.HA65.B.01093/21
0Ex ia IIC T6..T2 Ga X
- RU C-DE.HA65.B.01093/21
- CE-Marking
- ATEX-Directive 2014/34/EU
- PED Directive 2014/68/EU
- Material certificates 3.1, 3.2 acc. DIN EN10204:2004
- Metrology (Custody Transfer)
- OIML R117
Liquids other than water (EU Type Approval)
- OIML R117
- Marine
- DNV
- ABS